Enersys Datasafe HX Battery Datasheet

The DataSafe ® HX top terminal 12HX540-FR 12 123 540 13.3 338 6.8 173 10.7 272 106.0 48.1 4775 2.6 1 D 1.70 6.44 18.41 8.35 2 AM-HX-RS AA March 2018. Battery Range Summary Constant Power Discharge (Watts per Cell) to 1.75Vpc at 77°F (25°C) Constant Power Discharge (Watts per Cell) to 1.70Vpc at 77°F (25°C)

12HX540-FR BATTERY ENERSYS DATASAFE

Description 12HX540-FR BATTERY ENERSYS DATASAFE. 12HX540-FR BATTERY ENERSYS DATASAFE ENERSYS DATASAFE 12V 540 Watt SEALED Lead Acid AGM. EnerSys DataSafe 12HX540-FR valve regulated lead acid batteries have been designed to offer superior solutions for the Information Technology and Uninterruptible Power Supply markets. DataSafe HX

Baterías DataSAfe 12HX540 – BATERÍAS PARA UPS | BATERÍAS

BATERÍAS DATASAFE 12HX150R-FR 12V 38Ah BATERIAS PARA UPS APC RBC17 BATERIA LEOCH LPX6-200 6V200AH Inicio Productos Productos etiquetados "Baterías DataSAfe 12HX540" Mostrando los 2 resultados. Ver barra lateral. Mostrar 9 24 36 Comparar. Vista rápida. Añadir a la lista de deseos. BATERÍAS DATASAFE-12HX135RFR 12V28AH. COTIZAR

BATERÍAS DATASAFE 12HX540FR 12V 123AH –

BATERÍAS DATASAFE-12HX540FR 12V 123Ah. Las Baterías DataSafe cuentan con tecnología de plomo ácido regulado por válvula (vrla), las baterías DataSafe HX ofrecen soluciones superiores para una amplia gama de sistemas de

Enersys Datasafe 12HX540 119Ah 12Vdc Batteries

Enersys Datasafe 12HX540 119Ah 12Vdc value regulated lead acid (VRLA) batteries with a 10year design life for use in high rate discharge applications including UPS systems. The DataSafe HX top terminal batteries gas recombination technology and are designed for superior performance and excellent service life.

EnerSys DataSafe 12HX540FR Lead Acid Battery

EnerSys DataSafe HX Series EnerSys DataSafe HX Series 12HX540FR 12 Volt / 123 Ah @8 Hr with Recessed M6 Terminals. SKU: EN-12HX540RFR Categories: 12HX540, Brands, Chemistry, DataSafe, EnerSys, HX Series,

DataSafe HX Series Installation, Operation And Maintenance

View and Download DataSafe HX Series installation, operation and maintenance instructions online. Top Terminated Batteries 6 and 12 Volt. HX Series camera accessories pdf manual download. Also for: 12hx205, 12hx300, 12hx330, 12hx400, 12hx505, 12hx540, 6hx800.

Battery Range Summary

The DataSafe® HX range of valve regulated lead acid batteries has been designed to offer superior solutions for the Uninterruptible Power Supply (UPS) and Information Technology markets. DataSafe HX batteries are the ideal source of power to protect vital systems and incorporates select design features that maximise reliability

Limited Product Warranty DataSafe 12HX205-12HX540,

EnerSys Delaware Inc. ("EnerSys") warrants its DataSafe® 12HX205-12HX540, 16HX, 12HX680 Valve Regulated Lead Acid (VRLA) UPS float service batteries, racks and cabinets against defective materials and workmanship for the full period as defined

DataSafe® HX and HX+ Performance Data

DataSafe HX Battery Type 5 101520 30 45 60 Standby Time (Minutes) DataSafe HX+ Battery Type 5 101520 30 45 60 Standby Time (Minutes) 12HX540 897.5674.8531.7438.5235.9186.2 326.3 . Constant Power Discharge Performance Data Constant Power (Watts per cell) to

Baterías DataSafe® HX

Baterías DataSafe® HX Las baterías DataSafe ® HX, con tecnología VRLA (plomo-ácido con regulación por válvula), ofrecen soluciones superiores para una amplia gama de sistemas de alimentación ininterrumpida (SAI) y aplicaciones informáticas. Estas baterías combinan una serie de características de diseño exclusivas para maximizar su fiabilidad y su vida útil,

Battery Performance Specifications

Publication No: US-HXTEL-PS-001 - September 2014 EnerSys World Headquarters 2366 Bernville Road, Reading, PA 19605, USA Tel: +1-610-208-1991 / +1-800-538-3627 EnerSys EMEA EH Europe GmbH, Löwenstrasse 32, 8001 Zurich, Switzerland Tel: +41 44 215 7410 EnerSys Asia 152 Beach Road, Gateway East Building #11-03, Singapore

Enersys 12HX330 Datasafe Battery Data Sheet

The DataSafe ® HX top terminal 12HX540-FR 12 123 540 13.3 338 6.8 173 10.7 272 106.0 48.1 4775 2.6 1 D 1.70 6.44 18.41 8.35 2 AM-HX-RS AA March 2018. Battery Range Summary Constant Power Discharge (Watts per Cell) to 1.75Vpc at 77°F (25°C) Constant Power Discharge (Watts per Cell) to 1.70Vpc at 77°F (25°C)

EnerSys DataSafe HX 12HX50

The DataSafe HX 12HX50''s front terminal scales to larger Kva systems, including 550, 800, and 925 watts per cell (WPC). All DataSafe HX batteries have a 10-year life expectancy and arrive at 100% initial battery capacity. Use in conjunction with a flame-repellant case and cover and a Front Terminal DataSafe cabinet for highest energy density.

Baterías DataSafe® HX

Diseñadas para UPS y tecnologías de la información IT. Las baterías DataSafe® HX son baterias robustas, con tecnologia AGM, y de válvula regulada de ácido-plomo,, su rendimiento y

EnerSys DataSafe 12HX540FR Lead Acid Battery

EnerSys DataSafe HX Series EnerSys DataSafe HX Series 12HX540FR 12 Volt / 123 Ah @8 Hr with Recessed M6 Terminals. SKU: EN-12HX540RFR Categories: 12HX540, Brands, Chemistry, DataSafe, EnerSys, HX Series, Lead Acid Tags: 12HX540, 12HX540FR, DataSafe, EnerSys, HX Series, Lead Acid. As low as $ 292.96 each.

DataSafe HX 12V Top Terminated Battery Installation

12HX540-FR 31.0 6.1 Charging Current The recommended charging method for DataSafe HX batteries is current limited, constant voltage charging. Refer to Table 1 for the current limits for each battery model. State of Charge The battery state of

Battery Range Summary

The DataSafe ® HX range of Valve 12HX205 - 12HX540: -30°C to +50°C Recommended: 20°C to 25°C • Up to six months shelf life (@ 25°C) Standards • UL listing: file numbers MH16464 for 12HX25 - 12HX150 and MH12544 for 12HX205 - 12HX540 •

12HX540-FR ENERSYS, DATASAFE Valve-Regulated Lead Acid

Buy 12HX540-FR - ENERSYS - DATASAFE Valve-Regulated Lead Acid Battery. Newark Electronics offers fast quotes, same day dispatch, fast delivery, wide inventory, datasheets & technical support.

DataSafe HX & HX Plus Performance Data

DataSafe HX Battery Type 5 101520 30 45 60 Standby Time (Minutes) DataSafe HX+ Battery Type 5 101520 30 45 60 Standby Time (Minutes) 12HX540 897.5674.8531.7438.5235.9186.2 326.3 . Constant Power Discharge Performance Data Constant Power (Watts per cell) to

Datasafe 12hx540 Dominica

6 FAQs about [Datasafe 12hx540 Dominica]

What is datasafe HX 12hx540?

The DataSafe HX 12HX540 features AGM VRLA (Absorbed Glass Mat Valve Regulated Lead Acid) technology and optimized electrochemistry. It is only manufactured in EnerSys 9001:2008 registered production facilities to guarantee quality and safety standards.

Who sells datasafe 12hx540 batteries?

Power Storage Solutions is a premier platinum stocking Distributor for the Datasafe 12HX540 batteries. We maintain the batteries in a climate controlled environment, then charge and test each unit prior to shipment.

Can datasafe HX batteries be installed on a base?

DataSafe HX top terminated batteries are designed to be installed on their base. Consult your local EnerSys® dealer before installing in any other orientation 2014 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates unless otherwise noted.

How long does the HX 12hx540 last?

It is only manufactured in EnerSys 9001:2008 registered production facilities to guarantee quality and safety standards. The HX 12HX540 is rated at 100% capacity at initial discharge and can be expected to last for 10 years. A cabinet and flame-retardant cover and case are available for separate purchase.

What is the maximum discharge voltage for a datasafe® HX battery?

The end of discharge voltage must be limited to 1.60Vpc. A protecting system shall have to be installed to prevent deep discharge. DataSafe® HX batteries must not be left in a discharged condition after supplying the load, but must be immediately returned to float recharge mode.

How long do datasafe HX top terminated batteries last?

Storage time: DataSafe HX top terminated batteries can be stored for up to 6 months at 77°F (25°C) before a freshening charge is required. At higher temperatures this time interval will be reduced DataSafe HX top terminated batteries are designed to be installed on their base.